24/7 Emergency Service

National Heating and Air Conditioning is here to help with 24/7 emergency HVAC services. Call us today at 513-621-4620 if you have an urgent issue in the Greater Cincinnati area! Whether your heat won’t come on during a cold snap or you’re struggling with no AC in the summer, our expert HVAC professionals are available day or night.

Heating & Air Conditioning Services in Cincinnati, OH 45243

Madeira and Indian Hill stretch along some of Cincinnati’s busiest east side corridors, including Camargo Road, Miami Avenue, and Kenwood Road. Between older Cape Cod homes near downtown Madeira, larger properties throughout Indian Hill, and finished basements common around Sellman Park and McDonald Commons, homeowners here deal with a wide range of heating and cooling challenges throughout the year.

National Heating & Air Conditioning has been serving Cincinnati homeowners since 1930, and our technicians continue working throughout the 45243 area every week. If your furnace, AC system, heat pump, or water heater is struggling to keep up, call 513-621-4620 or contact National Heating & Air Conditioning online to schedule service.

A Long History of Serving Madeira & Indian Hill Homeowners

National Heating & Air Conditioning has been working in neighborhoods throughout Madeira and Indian Hill for generations. Homes near Euclid Avenue and downtown Madeira often date back to the 1940s and 1950s, while properties throughout Indian Hill tend to be larger custom homes that require multiple HVAC systems, zoning controls, and advanced humidity management. Our technicians regularly work near Miami Avenue, Camargo Road, Kugler Mill Road, and throughout the neighborhoods locals simply refer to as “The Village.”

We also service homes near Madeira Elementary, Indian Hill High School, and the residential streets surrounding Murray Avenue and Dawson Road. Because we already service so many homes throughout Madeira, Indian Hill, and the 45243 area, we understand the equipment setups, airflow problems, and seasonal comfort issues homeowners here run into year after year.

Air Conditioning & Cooling Services in Madeira & Indian Hill

Summer cooling problems throughout 45243 often go beyond simply replacing an AC unit. Older Madeira homes with original layouts can struggle with uneven airflow between floors, while larger Indian Hill homes may rely on several separate systems working together to cool the property evenly. National Heating & Air Conditioning provides:

  • AC Repair
  • Emergency AC Repair
  • AC Installation
  • AC Replacement
  • AC Maintenance
  • Ductless Mini-Splits
  • Heat Pumps

Heating Services in Madeira & Indian Hill

Winters in Cincinnati place a heavy workload on heating systems, especially in older homes with aging furnaces, original ductwork, or boiler systems that have been operating for decades. The colder-than-average winter conditions at the end of 2025 caused a noticeable increase in furnace strain throughout 45243, particularly in homes with older heat exchangers and neglected maintenance. Heating services available throughout Cincinnati’s east side include:

  • Emergency Heating Repair
  • Heating Repair
  • Heating Installation
  • Heating Replacement
  • Heating Maintenance
  • Furnaces
  • Boilers
  • Geothermal Service
  • Heat Pumps

Boiler systems are still common throughout parts of Madeira and Indian Hill, especially in older brick homes near Euclid Avenue, Given Road, and sections surrounding downtown Madeira that were built before central air became standard.

Water Heater Services in Madeira & Indian Hill

Finished basements are extremely common throughout neighborhoods near Camargo Club, Madeira neighborhoods off Hosbrook Road, and many homes throughout Indian Hill, which means water heater failures can quickly turn into expensive cleanup situations. We regularly help homeowners replace aging tank water heaters before leaks damage flooring, drywall, or storage areas. National Heating & Air Conditioning provides:

  • Water Heater Installation
  • Water Heater Repair
  • Tankless Water Heaters
  • Tankless Water Heater Installation
  • Tankless Water Heater Repair

Many homes throughout Madeira still have older water heaters approaching the end of their lifespan, especially in homes built during the post-war housing boom. Hard water buildup can also reduce efficiency over time and shorten the lifespan of heating elements and internal components. Tankless systems have also become more popular throughout Indian Hill and newer renovated homes where homeowners want longer hot water supply, improved efficiency, and more usable mechanical room space.

Commercial HVAC Services in Madeira & Indian Hill

Madeira and Indian Hill include a mix of professional offices, restaurants, schools, churches, and local businesses throughout the Miami Avenue corridor, Kenwood Road, and areas surrounding Madeira’s downtown business district. Commercial systems here often require careful maintenance because many buildings are older and were renovated over time. Commercial HVAC services include:

  • Commercial AC
  • Commercial Heating
  • Commercial Boilers
  • Commercial Heat Pumps

We regularly work with commercial properties that rely on older boiler systems, rooftop equipment, or multi-zone configurations to keep larger spaces comfortable. Churches, schools, and institutional buildings throughout this part of Cincinnati often require specialized airflow management because of tall ceilings and older building layouts.

Why Homeowners Throughout Madeira & Indian Hill Continue Choosing National Heating & Air Conditioning

Homeowners throughout Madeira and Indian Hill continue calling National Heating & Air Conditioning because they want technicians who explain problems honestly and take the time to solve them correctly. Our team already works throughout Madeira, Indian Hill, Terrace Park, and nearby east side neighborhoods every week, allowing us to respond quickly when homeowners need service.

Homeowners throughout Madeira, Indian Hill, and 45243 continue choosing National Heating & Air Conditioning because we provide:

  • Experienced HVAC technicians
  • Emergency repair availability
  • Long-term local service history dating back to 1930
  • Honest recommendations without pressure
  • Maintenance plans for long-term system performance
  • Help with both older and high-efficiency equipment
  • Clear communication throughout the repair process

Homes throughout Madeira and Indian Hill often contain a combination of older infrastructure and modern upgrades, which requires technicians who know how to work with both aging systems and newer high-efficiency technology.

What Cincinnati Area Customers Are Saying

“Kevin Gaines is awesome. He’s friendly and so competent. He answered many questions I asked about the furnace. I had questions about the water heater as well and he went the extra mile to send pictures and get answers from the proper person. I’m sold on the company thanks to Kevin!”

Gerald Y. – Rated 5/5 Stars

“We couldn’t be more pleased with Kevin’s services this week. He assessed the problem for us on Sunday and had our heat pump back up on Wednesday. Kept the temperature needed in furnace mode in between. We’re in Florida most of the year, so we’re totally dependent on his skills.”

Jan J. – Rated 5/5 Stars

“Jonathan Eaves was very kind and helpful. Checked out system and was able to fix a small issue quickly and also explain how we can prevent the issue from reoccurring. Wonderful service right before a large snow storm!”

Billy T. – Rated 5/5 Stars

Schedule HVAC or Water Heater Service in Madeira & Indian Hill

If your home in Madeira, Indian Hill, Miami Hills, Terrace Park, or the surrounding east side communities needs heating, cooling, geothermal, commercial HVAC, or water heater service, National Heating & Air Conditioning is ready to help. Our technicians already work throughout this part of Cincinnati every week and understand the types of systems local homeowners rely on every season.

Call 513-621-4620 or contact National Heating & Air Conditioning online today to schedule service in Cincinnati, OH 45243.

Recent Jobs and Reviews in Cincinnati, OH

Job Locations and Reviews

Conducted site assessment for commercial packaged HVAC unit replacement. Documented existing electrical disconnect panel serving A/C Unit #4 with Square D breaker configuration and inspected exterior wall-mounted package unit on commercial building. Provided comprehensive replacement estimate for complete system installation.
Conducted site assessment for commercial packaged HVAC unit replacement. Documented existing electrical disconnect panel serving A/C Unit #4 with Square D breaker configuration and inspected exterior wall-mounted package unit on commercial building. Provided comprehensive replacement estimate for complete system installation.
Victoria M.
Victoria M. Checked in
Conducted site assessment for commercial packaged HVAC unit replacement. Documented existing electrical disconnect panel serving A/C Unit #4 with Square D breaker configuration and inspected exterior wall-mounted package unit on commercial building. Provided comprehensive replacement estimate for complete system installation.
Cincinnati, OH 45226
Completed full dual-zone HVAC system replacement including two rooftop heat pump units (Legacy 2.0-ton and 2.5-ton models utilizing R454B refrigerant) and two indoor FJ5 fan coil air handlers installed in utility closets. Installed two 10kw heat kits in the new air handlers to provide supplemental heating capacity. Replaced both thermostats to ensure proper system control and operation.

Purged linesets with nitrogen and performed comprehensive pressure leak testing to verify system integrity prior to charging. Reconfigured return air drop for the bedroom closet air handler to optimize airflow distribution for the new equipment specifications. Replaced filter rack on bedroom closet unit to accommodate new system requirements.

Installed new electrical disconnect boxes with fuses at both outdoor units to meet current code requirements. Replaced Bryant bypass humidifier on the hallway system to maintain proper indoor humidity levels. Reconnected both air handlers to existing drain lines
Completed full dual-zone HVAC system replacement including two rooftop heat pump units (Legacy 2.0-ton and 2.5-ton models utilizing R454B refrigerant) and two indoor FJ5 fan coil air handlers installed in utility closets. Installed two 10kw heat kits in the new air handlers to provide supplemental heating capacity. Replaced both thermostats to ensure proper system control and operation.

Purged linesets with nitrogen and performed comprehensive pressure leak testing to verify system integrity prior to charging. Reconfigured return air drop for the bedroom closet air handler to optimize airflow distribution for the new equipment specifications. Replaced filter rack on bedroom closet unit to accommodate new system requirements.

Installed new electrical disconnect boxes with fuses at both outdoor units to meet current code requirements. Replaced Bryant bypass humidifier on the hallway system to maintain proper indoor humidity levels. Reconnected both air handlers to existing drain lines
Erik M.
Erik M. Checked in
Completed full dual-zone HVAC system replacement including two rooftop heat pump units (Legacy 2.0-ton and 2.5-ton models utilizing R454B refrigerant) and two indoor FJ5 fan coil air handlers installed in utility closets. Installed two 10kw heat kits in the new air handlers to provide supplemental heating capacity. Replaced both thermostats to ensure proper system control and operation. Purged linesets with nitrogen and performed comprehensive pressure leak testing to verify system integrity prior to charging. Reconfigured return air drop for the bedroom closet air handler to optimize airflow distribution for the new equipment specifications. Replaced filter rack on bedroom closet unit to accommodate new system requirements. Installed new electrical disconnect boxes with fuses at both outdoor units to meet current code requirements. Replaced Bryant bypass humidifier on the hallway system to maintain proper indoor humidity levels. Reconnected both air handlers to existing drain lines
Cincinnati, OH 45226
Completed full HVAC system installation including Legacy 912SE42060M17 92% single-stage gas furnace, Legacy 134SAN02400N 14 SEER2 air conditioner with R454B refrigerant, and CVAVA2417XMA v-coil cased vertical evaporator coil. Replaced existing lineset, installed new outdoor condenser pad and disconnect box with fuses, replaced filter rack, and rebuilt partial return drop (24×8). Reconnected all systems to existing drain line, gas line, and flue pipes while retaining existing thermostat.
Completed full HVAC system installation including Legacy 912SE42060M17 92% single-stage gas furnace, Legacy 134SAN02400N 14 SEER2 air conditioner with R454B refrigerant, and CVAVA2417XMA v-coil cased vertical evaporator coil. Replaced existing lineset, installed new outdoor condenser pad and disconnect box with fuses, replaced filter rack, and rebuilt partial return drop (24×8). Reconnected all systems to existing drain line, gas line, and flue pipes while retaining existing thermostat.
Chris B.
Chris B. Checked in
Completed full HVAC system installation including Legacy 912SE42060M17 92% single-stage gas furnace, Legacy 134SAN02400N 14 SEER2 air conditioner with R454B refrigerant, and CVAVA2417XMA v-coil cased vertical evaporator coil. Replaced existing lineset, installed new outdoor condenser pad and disconnect box with fuses, replaced filter rack, and rebuilt partial return drop (24×8). Reconnected all systems to existing drain line, gas line, and flue pipes while retaining existing thermostat.
Cincinnati, OH 45218
Completed installation of a 1.5-ton Bryant ductless mini-split system for commercial application. Installed outdoor condensing unit on brick ledge with proper mounting, connected three Bryant high-wall indoor air handlers with refrigerant line sets and PVC condensate drainage routed vertically along exterior brick wall. Performed system startup, charged refrigerant to manufacturer specifications, tested all zones with digital manifold gauges to verify proper pressures and temperatures, and confirmed operational status of all thermostats and indoor units.
Completed installation of a 1.5-ton Bryant ductless mini-split system for commercial application. Installed outdoor condensing unit on brick ledge with proper mounting, connected three Bryant high-wall indoor air handlers with refrigerant line sets and PVC condensate drainage routed vertically along exterior brick wall. Performed system startup, charged refrigerant to manufacturer specifications, tested all zones with digital manifold gauges to verify proper pressures and temperatures, and confirmed operational status of all thermostats and indoor units.
Erik M.
Erik M. Checked in
Completed installation of a 1.5-ton Bryant ductless mini-split system for commercial application. Installed outdoor condensing unit on brick ledge with proper mounting, connected three Bryant high-wall indoor air handlers with refrigerant line sets and PVC condensate drainage routed vertically along exterior brick wall. Performed system startup, charged refrigerant to manufacturer specifications, tested all zones with digital manifold gauges to verify proper pressures and temperatures, and confirmed operational status of all thermostats and indoor units.
Cincinnati, OH 45243
Installed Bryant 927TA66100V21 two-stage gas furnace with 96% AFUE rating, featuring variable-speed constant torque ECM motor. Reconnected unit to existing evaporator coil, drain line, flue pipes, and gas line. Installed Bryant bypass humidifier with new water pad and completed combustion analysis testing, verifying proper temperature differential and system efficiency readings.
Installed Bryant 927TA66100V21 two-stage gas furnace with 96% AFUE rating, featuring variable-speed constant torque ECM motor. Reconnected unit to existing evaporator coil, drain line, flue pipes, and gas line. Installed Bryant bypass humidifier with new water pad and completed combustion analysis testing, verifying proper temperature differential and system efficiency readings.
Chris B.
Chris B. Checked in
Installed Bryant 927TA66100V21 two-stage gas furnace with 96% AFUE rating, featuring variable-speed constant torque ECM motor. Reconnected unit to existing evaporator coil, drain line, flue pipes, and gas line. Installed Bryant bypass humidifier with new water pad and completed combustion analysis testing, verifying proper temperature differential and system efficiency readings.
Cincinnati, OH 45202
Relocated complete HVAC system from ceiling to hallway closet, installing 1-Bryant FJ5ANXA18L00 air handler with 8 kW electric heat pack and 1-Bryant GA4SAN51800N 1.5-ton 14 SEER condenser with R-454B refrigerant. Flushed and extended existing refrigerant lines to new closet location, fabricated and installed sheet metal connections to existing supply and return ductwork, and completed miscellaneous ductwork modifications for proper airflow. Installed outdoor disconnect, whip, pad, and fuses, obtained permit, and left existing equipment on-site for maintenance purposes.
Relocated complete HVAC system from ceiling to hallway closet, installing 1-Bryant FJ5ANXA18L00 air handler with 8 kW electric heat pack and 1-Bryant GA4SAN51800N 1.5-ton 14 SEER condenser with R-454B refrigerant. Flushed and extended existing refrigerant lines to new closet location, fabricated and installed sheet metal connections to existing supply and return ductwork, and completed miscellaneous ductwork modifications for proper airflow. Installed outdoor disconnect, whip, pad, and fuses, obtained permit, and left existing equipment on-site for maintenance purposes.
Chris B.
Chris B. Checked in
Relocated complete HVAC system from ceiling to hallway closet, installing 1-Bryant FJ5ANXA18L00 air handler with 8 kW electric heat pack and 1-Bryant GA4SAN51800N 1.5-ton 14 SEER condenser with R-454B refrigerant. Flushed and extended existing refrigerant lines to new closet location, fabricated and installed sheet metal connections to existing supply and return ductwork, and completed miscellaneous ductwork modifications for proper airflow. Installed outdoor disconnect, whip, pad, and fuses, obtained permit, and left existing equipment on-site for maintenance purposes.
Cincinnati, OH 45249
Completed estimate for complete HVAC system replacement in residential utility closet with cramped working conditions. Assessed existing Trane furnace system with 100,000 BTU input capacity, current air filtration at 20x20x1 specification, and 2-3 inch PVC venting configuration. Documented existing equipment layout including furnace unit, air conditioning condenser, water heater, and associated ductwork in confined mechanical room with limited accessibility. Evaluated current installation featuring beige furnace with white louvered panel, silver metallic supply ductwork, gray PVC condensate piping with insulation tape, black flexible ducting, and copper refrigerant lines. Recommended humidifier replacement as part of system upgrade. Recorded technical specifications for replacement system including BTU ratings, air filter dimensions, condenser specifications, refrigerant piping requirements, electrical specifications, and thermostat placement. Photographed existing equipment arrangemen
Completed estimate for complete HVAC system replacement in residential utility closet with cramped working conditions. Assessed existing Trane furnace system with 100,000 BTU input capacity, current air filtration at 20x20x1 specification, and 2-3 inch PVC venting configuration. Documented existing equipment layout including furnace unit, air conditioning condenser, water heater, and associated ductwork in confined mechanical room with limited accessibility. Evaluated current installation featuring beige furnace with white louvered panel, silver metallic supply ductwork, gray PVC condensate piping with insulation tape, black flexible ducting, and copper refrigerant lines. Recommended humidifier replacement as part of system upgrade. Recorded technical specifications for replacement system including BTU ratings, air filter dimensions, condenser specifications, refrigerant piping requirements, electrical specifications, and thermostat placement. Photographed existing equipment arrangemen
Victoria M.
Victoria M. Checked in
Completed estimate for complete HVAC system replacement in residential utility closet with cramped working conditions. Assessed existing Trane furnace system with 100,000 BTU input capacity, current air filtration at 20x20x1 specification, and 2-3 inch PVC venting configuration. Documented existing equipment layout including furnace unit, air conditioning condenser, water heater, and associated ductwork in confined mechanical room with limited accessibility. Evaluated current installation featuring beige furnace with white louvered panel, silver metallic supply ductwork, gray PVC condensate piping with insulation tape, black flexible ducting, and copper refrigerant lines. Recommended humidifier replacement as part of system upgrade. Recorded technical specifications for replacement system including BTU ratings, air filter dimensions, condenser specifications, refrigerant piping requirements, electrical specifications, and thermostat placement. Photographed existing equipment arrangemen
Cincinnati, OH 45202
Conducted site assessment of existing rooftop R-22 commercial air conditioning system experiencing low refrigerant levels. Evaluated condenser unit condition, noting significant dirt accumulation on protective grille and aged equipment requiring replacement due to obsolete refrigerant type and system deterioration. Provided comprehensive replacement estimate for new commercial HVAC system installation.
Conducted site assessment of existing rooftop R-22 commercial air conditioning system experiencing low refrigerant levels. Evaluated condenser unit condition, noting significant dirt accumulation on protective grille and aged equipment requiring replacement due to obsolete refrigerant type and system deterioration. Provided comprehensive replacement estimate for new commercial HVAC system installation.
Tony A.
Tony A. Checked in
Conducted site assessment of existing rooftop R-22 commercial air conditioning system experiencing low refrigerant levels. Evaluated condenser unit condition, noting significant dirt accumulation on protective grille and aged equipment requiring replacement due to obsolete refrigerant type and system deterioration. Provided comprehensive replacement estimate for new commercial HVAC system installation.
Cincinnati, OH 45202
Conducted comprehensive estimate for complete air conditioning and gas furnace replacement system. Assessed existing basement mechanical room installation, documented current HVAC equipment including furnace with stainless steel panel, evaporator coil assembly, and ductwork configuration. Evaluated system components, photographed equipment specifications, and provided replacement options with promotional pricing consideration for dual-unit installation.
Conducted comprehensive estimate for complete air conditioning and gas furnace replacement system. Assessed existing basement mechanical room installation, documented current HVAC equipment including furnace with stainless steel panel, evaporator coil assembly, and ductwork configuration. Evaluated system components, photographed equipment specifications, and provided replacement options with promotional pricing consideration for dual-unit installation.
Victoria M.
Victoria M. Checked in
Conducted comprehensive estimate for complete air conditioning and gas furnace replacement system. Assessed existing basement mechanical room installation, documented current HVAC equipment including furnace with stainless steel panel, evaporator coil assembly, and ductwork configuration. Evaluated system components, photographed equipment specifications, and provided replacement options with promotional pricing consideration for dual-unit installation.
Cincinnati, OH 45243
Completed full commercial HVAC system replacement including installation of Bryant FMA5X2400AL R-454B air handler with 8kw electric heat pack and Bryant GA4SAN51800N 1.5-ton 14 SEER condenser utilizing R-454B refrigerant. Flushed and reused existing refrigerant lines, fabricated sheet metal connections to integrate with existing supply and return ductwork, installed outdoor disconnect with whip, pad, and fuses, obtained necessary permit, and disposed of existing equipment per EPA specifications with old unit left on-site per maintenance request.
Completed full commercial HVAC system replacement including installation of Bryant FMA5X2400AL R-454B air handler with 8kw electric heat pack and Bryant GA4SAN51800N 1.5-ton 14 SEER condenser utilizing R-454B refrigerant. Flushed and reused existing refrigerant lines, fabricated sheet metal connections to integrate with existing supply and return ductwork, installed outdoor disconnect with whip, pad, and fuses, obtained necessary permit, and disposed of existing equipment per EPA specifications with old unit left on-site per maintenance request.
Erik M.
Erik M. Checked in
Completed full commercial HVAC system replacement including installation of Bryant FMA5X2400AL R-454B air handler with 8kw electric heat pack and Bryant GA4SAN51800N 1.5-ton 14 SEER condenser utilizing R-454B refrigerant. Flushed and reused existing refrigerant lines, fabricated sheet metal connections to integrate with existing supply and return ductwork, installed outdoor disconnect with whip, pad, and fuses, obtained necessary permit, and disposed of existing equipment per EPA specifications with old unit left on-site per maintenance request.
Cincinnati, OH 45249
Responded to no cooling complaint following commercial AC installation. Upon arrival, verified thermostat was set to cooling mode with setpoint at 50°F and indoor temperature reading 75°F. Inspected system operation and measured supply air temperature at ceiling diffuser, confirming 55°F discharge air temperature. Checked service valves on outdoor unit that may have been inadvertently left closed during installation. Opened valves to proper operating position, restoring full refrigerant flow to system. System now cooling properly with appropriate temperature differential.
Responded to no cooling complaint following commercial AC installation. Upon arrival, verified thermostat was set to cooling mode with setpoint at 50°F and indoor temperature reading 75°F. Inspected system operation and measured supply air temperature at ceiling diffuser, confirming 55°F discharge air temperature. Checked service valves on outdoor unit that may have been inadvertently left closed during installation. Opened valves to proper operating position, restoring full refrigerant flow to system. System now cooling properly with appropriate temperature differential.
Giancarlo L.
Giancarlo L. Checked in
Responded to no cooling complaint following commercial AC installation. Upon arrival, verified thermostat was set to cooling mode with setpoint at 50°F and indoor temperature reading 75°F. Inspected system operation and measured supply air temperature at ceiling diffuser, confirming 55°F discharge air temperature. Checked service valves on outdoor unit that may have been inadvertently left closed during installation. Opened valves to proper operating position, restoring full refrigerant flow to system. System now cooling properly with appropriate temperature differential.
Cincinnati, OH 45248
Conducted comprehensive assessment of existing HVAC system for complete replacement estimate. Evaluated gas furnace and air conditioning equipment located in basement installation. Documented current forced-air heating unit with gray metal casing, associated ductwork configuration, and PVC condensate drainage system. Inspected existing thermostat control wiring and terminal connections to determine compatibility requirements for new equipment installation. Photographed equipment specifications, spatial constraints, and existing infrastructure to develop accurate replacement proposal for complete heating and cooling system upgrade.
Conducted comprehensive assessment of existing HVAC system for complete replacement estimate. Evaluated gas furnace and air conditioning equipment located in basement installation. Documented current forced-air heating unit with gray metal casing, associated ductwork configuration, and PVC condensate drainage system. Inspected existing thermostat control wiring and terminal connections to determine compatibility requirements for new equipment installation. Photographed equipment specifications, spatial constraints, and existing infrastructure to develop accurate replacement proposal for complete heating and cooling system upgrade.
Victoria M.
Victoria M. Checked in
Conducted comprehensive assessment of existing HVAC system for complete replacement estimate. Evaluated gas furnace and air conditioning equipment located in basement installation. Documented current forced-air heating unit with gray metal casing, associated ductwork configuration, and PVC condensate drainage system. Inspected existing thermostat control wiring and terminal connections to determine compatibility requirements for new equipment installation. Photographed equipment specifications, spatial constraints, and existing infrastructure to develop accurate replacement proposal for complete heating and cooling system upgrade.
Cincinnati, OH 45218
Completed full commercial HVAC system installation including Bryant GA4SAN52400 air conditioning condenser unit and BCRMA2124S3N3 ADP fan coil. Installed condenser unit on exterior gravel pad with proper mounting and positioning against brick wall. Fabricated and installed custom sheet metal ductwork to connect new fan coil to existing duct system. Installed electrical disconnect switch, whip, and fuses for both indoor and outdoor units. Wired system to existing electrical panel and labeled new circuits accordingly. Verified all electrical connections, tested system startup and operation, and confirmed proper airflow and cooling performance throughout.
Completed full commercial HVAC system installation including Bryant GA4SAN52400 air conditioning condenser unit and BCRMA2124S3N3 ADP fan coil. Installed condenser unit on exterior gravel pad with proper mounting and positioning against brick wall. Fabricated and installed custom sheet metal ductwork to connect new fan coil to existing duct system. Installed electrical disconnect switch, whip, and fuses for both indoor and outdoor units. Wired system to existing electrical panel and labeled new circuits accordingly. Verified all electrical connections, tested system startup and operation, and confirmed proper airflow and cooling performance throughout.
Chris B.
Chris B. Checked in
Completed full commercial HVAC system installation including Bryant GA4SAN52400 air conditioning condenser unit and BCRMA2124S3N3 ADP fan coil. Installed condenser unit on exterior gravel pad with proper mounting and positioning against brick wall. Fabricated and installed custom sheet metal ductwork to connect new fan coil to existing duct system. Installed electrical disconnect switch, whip, and fuses for both indoor and outdoor units. Wired system to existing electrical panel and labeled new circuits accordingly. Verified all electrical connections, tested system startup and operation, and confirmed proper airflow and cooling performance throughout.
Cincinnati, OH 45243
Completed full commercial HVAC system installation including Bryant 2-ton 14 SEER condenser (GA4SAN52400N) rated for R-454B refrigerant and hot water fan coil unit (BCRMA2124S3N3). Installed electrical disconnect with 25-amp fuses, whip and pad, fabricated custom sheet metal to connect to existing supply and return ductwork, and installed return air box with filter rack. Added purge valves to boiler lines, performed complete refrigerant leak check, and properly charged system to manufacturer specifications. Disposed of existing equipment per EPA regulations and utilized crane for rooftop equipment placement. Obtained necessary permit and system is operational.
Completed full commercial HVAC system installation including Bryant 2-ton 14 SEER condenser (GA4SAN52400N) rated for R-454B refrigerant and hot water fan coil unit (BCRMA2124S3N3). Installed electrical disconnect with 25-amp fuses, whip and pad, fabricated custom sheet metal to connect to existing supply and return ductwork, and installed return air box with filter rack. Added purge valves to boiler lines, performed complete refrigerant leak check, and properly charged system to manufacturer specifications. Disposed of existing equipment per EPA regulations and utilized crane for rooftop equipment placement. Obtained necessary permit and system is operational.
Erik M.
Erik M. Checked in
Completed full commercial HVAC system installation including Bryant 2-ton 14 SEER condenser (GA4SAN52400N) rated for R-454B refrigerant and hot water fan coil unit (BCRMA2124S3N3). Installed electrical disconnect with 25-amp fuses, whip and pad, fabricated custom sheet metal to connect to existing supply and return ductwork, and installed return air box with filter rack. Added purge valves to boiler lines, performed complete refrigerant leak check, and properly charged system to manufacturer specifications. Disposed of existing equipment per EPA regulations and utilized crane for rooftop equipment placement. Obtained necessary permit and system is operational.
Cincinnati, OH 45248
Conducted comprehensive attic inspection to assess existing air conditioning system and provide replacement estimate. Evaluated attic-mounted HVAC equipment, existing ductwork configuration, structural access points, and insulation conditions. Documented current system layout including flexible duct routing, PVC condensate drainage, ventilation pathways, and available clearances for equipment replacement. Photographed attic space showing wooden framing, existing black flexible ductwork, insulation materials, and brick chimney structure to support replacement recommendations and equipment sizing calculations.
Conducted comprehensive attic inspection to assess existing air conditioning system and provide replacement estimate. Evaluated attic-mounted HVAC equipment, existing ductwork configuration, structural access points, and insulation conditions. Documented current system layout including flexible duct routing, PVC condensate drainage, ventilation pathways, and available clearances for equipment replacement. Photographed attic space showing wooden framing, existing black flexible ductwork, insulation materials, and brick chimney structure to support replacement recommendations and equipment sizing calculations.
Victoria M.
Victoria M. Checked in
Conducted comprehensive attic inspection to assess existing air conditioning system and provide replacement estimate. Evaluated attic-mounted HVAC equipment, existing ductwork configuration, structural access points, and insulation conditions. Documented current system layout including flexible duct routing, PVC condensate drainage, ventilation pathways, and available clearances for equipment replacement. Photographed attic space showing wooden framing, existing black flexible ductwork, insulation materials, and brick chimney structure to support replacement recommendations and equipment sizing calculations.
Cincinnati, OH 45213
Performed diagnostic evaluation on mini split system experiencing operational failure. Identified faulty primary control board outputting incorrect voltage to indoor unit, preventing proper system operation. Determined replacement parts are unavailable for this unit, and complete system replacement is required to restore functionality.
Performed diagnostic evaluation on mini split system experiencing operational failure. Identified faulty primary control board outputting incorrect voltage to indoor unit, preventing proper system operation. Determined replacement parts are unavailable for this unit, and complete system replacement is required to restore functionality.
Victoria M.
Victoria M. Checked in
Performed diagnostic evaluation on mini split system experiencing operational failure. Identified faulty primary control board outputting incorrect voltage to indoor unit, preventing proper system operation. Determined replacement parts are unavailable for this unit, and complete system replacement is required to restore functionality.
Cincinnati, OH 45236
Completed full HVAC system replacement including installation of Bryant 987MC66100C21 Evolution 100,000 BTU gas furnace, 148TAN04800W Preferred 18 SEER2 air conditioner (4.0 tons, two-stage, R454B refrigerant), and CVAVA4821XMA V-coil cased vertical evaporator coil in basement utility room. Performed lineset replacement with nitrogen purge, installed new outdoor disconnect with fuses, and reconnected all utilities including gas line, condensate drain line, and filter rack. Reused existing zoning system, replaced thermostat(s), and installed new Model 501 filter in existing filter rack to complete system commissioning.
Completed full HVAC system replacement including installation of Bryant 987MC66100C21 Evolution 100,000 BTU gas furnace, 148TAN04800W Preferred 18 SEER2 air conditioner (4.0 tons, two-stage, R454B refrigerant), and CVAVA4821XMA V-coil cased vertical evaporator coil in basement utility room. Performed lineset replacement with nitrogen purge, installed new outdoor disconnect with fuses, and reconnected all utilities including gas line, condensate drain line, and filter rack. Reused existing zoning system, replaced thermostat(s), and installed new Model 501 filter in existing filter rack to complete system commissioning.
Erik M.
Erik M. Checked in
Completed full HVAC system replacement including installation of Bryant 987MC66100C21 Evolution 100,000 BTU gas furnace, 148TAN04800W Preferred 18 SEER2 air conditioner (4.0 tons, two-stage, R454B refrigerant), and CVAVA4821XMA V-coil cased vertical evaporator coil in basement utility room. Performed lineset replacement with nitrogen purge, installed new outdoor disconnect with fuses, and reconnected all utilities including gas line, condensate drain line, and filter rack. Reused existing zoning system, replaced thermostat(s), and installed new Model 501 filter in existing filter rack to complete system commissioning.
Cincinnati, OH 45227
Completed full HVAC system replacement including installation of Legacy 912SE42060M17 92% single-stage gas furnace, Legacy 134SAN03000N 14 SEER2 air conditioner with R454B refrigerant, and CVAVA3017XMA V-coil cased vertical evaporator coil. Performed nitrogen flush of existing lineset, replaced condensate pump, and installed new outdoor equipment pad with new disconnect box and fuses. Reconnected furnace to existing flue pipes and gas line, retained existing humidifier and filter rack, replaced humidifier pad, and installed new thermostat to complete system commissioning.
Completed full HVAC system replacement including installation of Legacy 912SE42060M17 92% single-stage gas furnace, Legacy 134SAN03000N 14 SEER2 air conditioner with R454B refrigerant, and CVAVA3017XMA V-coil cased vertical evaporator coil. Performed nitrogen flush of existing lineset, replaced condensate pump, and installed new outdoor equipment pad with new disconnect box and fuses. Reconnected furnace to existing flue pipes and gas line, retained existing humidifier and filter rack, replaced humidifier pad, and installed new thermostat to complete system commissioning.
Chris B.
Chris B. Checked in
Completed full HVAC system replacement including installation of Legacy 912SE42060M17 92% single-stage gas furnace, Legacy 134SAN03000N 14 SEER2 air conditioner with R454B refrigerant, and CVAVA3017XMA V-coil cased vertical evaporator coil. Performed nitrogen flush of existing lineset, replaced condensate pump, and installed new outdoor equipment pad with new disconnect box and fuses. Reconnected furnace to existing flue pipes and gas line, retained existing humidifier and filter rack, replaced humidifier pad, and installed new thermostat to complete system commissioning.
Cincinnati, OH 45223
Completed rooftop unit replacement and exercise room HVAC system installation at commercial facility. Removed existing equipment and installed new packaged rooftop air handling unit with proper electrical conduit connections and refrigerant line routing. Verified proper clearances and mounting on ballasted paver roof system, ensuring adequate spacing between equipment and building components as documented with field measurements.
Completed rooftop unit replacement and exercise room HVAC system installation at commercial facility. Removed existing equipment and installed new packaged rooftop air handling unit with proper electrical conduit connections and refrigerant line routing. Verified proper clearances and mounting on ballasted paver roof system, ensuring adequate spacing between equipment and building components as documented with field measurements.
Victoria M.
Victoria M. Checked in
Completed rooftop unit replacement and exercise room HVAC system installation at commercial facility. Removed existing equipment and installed new packaged rooftop air handling unit with proper electrical conduit connections and refrigerant line routing. Verified proper clearances and mounting on ballasted paver roof system, ensuring adequate spacing between equipment and building components as documented with field measurements.
Cincinnati, OH 45226
Completed heat pump system replacement for unit #2 located in upflow utility closet configuration. Replaced existing Bryant air handler (model 214DNL) with new equipment, including installation of associated ductwork modifications to accommodate 20" and 29" height specifications. Updated thermostat and replaced air filter with 16½" width unit, ensuring proper integration with existing Aprilaire humidifier system and galvanized metal ductwork.
Completed heat pump system replacement for unit #2 located in upflow utility closet configuration. Replaced existing Bryant air handler (model 214DNL) with new equipment, including installation of associated ductwork modifications to accommodate 20" and 29" height specifications. Updated thermostat and replaced air filter with 16½" width unit, ensuring proper integration with existing Aprilaire humidifier system and galvanized metal ductwork.
Victoria M.
Victoria M. Checked in
Completed heat pump system replacement for unit #2 located in upflow utility closet configuration. Replaced existing Bryant air handler (model 214DNL) with new equipment, including installation of associated ductwork modifications to accommodate 20" and 29" height specifications. Updated thermostat and replaced air filter with 16½" width unit, ensuring proper integration with existing Aprilaire humidifier system and galvanized metal ductwork.
Cincinnati, OH 45226

financing Image

Tax Credits and Price Match

Find Out Your Savings Options
financing Image
Found a better price? We'll meet or beat it!

Price Match guarantee

What To Expect Discover the National Difference
Satisfaction Guaranteed

Your comfort is our top priority, so we'll work tirelessly to guarantee you're 100% satisfied with our service.

Over 90 Years Experience

We have been providing HVAC services since 1931, so we have the experience to solve any of your problems.

Trained Technicians

Our team stays up to date with and continuously trains on all the latest HVAC technologies.

24/7 Emergency Service

HVAC systems choose the worst times to breakdown, so we're available nights, weekends, and holidays to help!

Upfront, Honest Pricing

We offer free estimates and price matching on all major equipment purchases. We’ll match any competitor's price as long as the equipment is an “apples-to-apples” comparison.

Convenient Financing

Costs should never be a barrier to receiving the services you need, so our team offers financing options, subject to approved credit.

Satisfaction Guaranteed

Your comfort is our top priority, so we'll work tirelessly to guarantee you're 100% satisfied with our service.

Over 90 Years Experience

We have been providing HVAC services since 1931, so we have the experience to solve any of your problems.

Trained Technicians

Our team stays up to date with and continuously trains on all the latest HVAC technologies.

24/7 Emergency Service

HVAC systems choose the worst times to breakdown, so we're available nights, weekends, and holidays to help!

Upfront, Honest Pricing

We offer free estimates and price matching on all major equipment purchases. We’ll match any competitor's price as long as the equipment is an “apples-to-apples” comparison.

Convenient Financing

Costs should never be a barrier to receiving the services you need, so our team offers financing options, subject to approved credit.

Our Reviews

What Our Clients Are Saying

Brandon of National Heating did an excellent job servicing my AC. He is very thorough, knowledgeable, and professional. He discovered that the low outside temperature sensor had not been set up on my Evolution Connex Control and took care of it. I appreciated his top-notch service!

Thomas S.

Great company that I trust. Very thorough. I just had my air conditioner annual service. I used Help in the past. They always tried to upsell every opportunity they had. National Heating and A/C is the real deal from booking the appointment to the actual work. Every person I have dealt with is kind, knowledgeable, and…

Paul M.

I can highly recommend National (previously Nelson Comfort) Heating and Air especially if Sanjay is the company representative. He was beyond good in that he completely cleaned the outside unit and was very thorough with the ac equipment inside the house. He even destroyed a wasp nest that I had not noticed. Five stars for this…

Susan S.

Excellent experience all around. Communication from the company was timely and complete. My service technician Chad Wilson was very knowledgeable, efficient and helpful. I had a lot of questions, having just moved into a house with systems that were unfamiliar to me (geothermal, radiant heat). Chad answered all my questions and spent extra time helping me…

Mary C.

My family has been using this company for years. They've always provided us with honest feedback on pricing for repairs and maintenance. This means a lot to a family on a tight budget. We never feel like we are charged for unnecessary items. All charges are explained and examined in great detail before being followed through.…

Megan K.